Restore: verify_database_file and restore_from_file run through
_run_in_executor; the upload is also opened read-only with
PRAGMA trusted_schema=OFF and refused when sqlite_master lists a trigger
or a view (a prompts database has neither, a crafted one could use them
to run SQL against the live data); at most MAX_SAFETY_BACKUPS (10)
'<db>.backup_*' files are kept next to the live database, oldest first.
Responses: backup_created and the maintenance statistics database_path
go through _public_path, and backup/restore failure messages through
_public_error, so no absolute server path appears in an admin body.
Add _read_json_body(request, max_bytes=1_000_000) to py/api: reads the
body in chunks, answers 413 past the cap (declared or streamed) and 400
for invalid or non-object JSON. Every JSON POST in the admin and logging
handlers goes through it; it is exposed as PromptManagerAPI._read_json_body
for the other route mixins.
Add _acquire_long_job(name) / _long_job_busy_response(label) on the API
object: one asyncio.Lock per job family, handed out as an async context
manager or None when busy, so a handler answers 409 instead of starting a
second scan. The duplicate scan and delete share the 'duplicates' family.
test_image_monitor_singleton replaced utils.comfyui_integration in
sys.modules with a MagicMock and never restored it, so running it before
test_comfyui_integration failed eight tests. The mock was unused; drop it
and install the server stub with setdefault in every owned test module.
The PromptSearchList IS_CHANGED test slept 10 ms between two time.time()
reads; the Windows clock ticks every 15.6 ms, so it was flaky there. Mock
the clock with an incrementing counter instead.
The diagnostics message no longer carries the absolute path, the restore test
closes its raw sqlite connections before the live file is replaced, the logs
tests declare their own folder_paths base directory, and the isolated logger
filters every handler to the test thread.
Route tests for stats, cleanup, duplicate scan/delete, settings,
diagnostics, test-link, maintenance (every operation, success and
failure), the output scan internals, and contract-level tests for
backup/restore (status codes and envelope only).
get_settings located the ImageMonitor singleton by scanning sys.modules
for any module with 'image_monitor' in its name, a workaround for the
package being importable under two identities. It now uses the same
try-package / except-top-level import as the rest of the API
(_current_image_monitor) and falls back to the configured roots when no
monitor is running.
The duplicate scan walked the output tree and hashed every file on the
aiohttp event loop, and the duplicate delete removed files inline; the
output scan ran its per-file database work one executor hop at a time.
- _find_duplicate_images_sync / _describe_media_file do the walk and
hashing; find_duplicate_images() runs them via _run_in_executor.
- _delete_duplicate_images_sync / _delete_one_duplicate do the removal
(absolute or output-relative paths) off the loop.
- The output scan is split into _collect_output_media_sync,
_extract_batch_metadata_sync and _ingest_scan_batch_sync (one
executor call per batch for all DB work) with a small SSE generator.
- Media collection is shared and de-duplicates by normcase'd path.
Settings, diagnostics, duplicate/output scans and the logging endpoints
returned absolute filesystem paths, and several error envelopes echoed
str(e) which for OSError carries the full path.
- _public_path() renders a path relative to the ComfyUI base directory
(folder_paths.base_path, else the output dir's parent) or to the
parent of an opted-in extra gallery root, falling back to the
basename; _public_error() reduces OSError to strerror + basename.
- GET /settings returns gallery roots and monitored directories in that
form; POST /settings resolves relative roots against the same anchors
(GalleryConfig.resolve_gallery_root) so the GET output round-trips.
- Diagnostics output_dirs, monitored_directories and the missing-DB
message no longer carry absolute paths; the image monitor is reached
through the package-or-top-level import fallback instead of a
three-dot relative import that failed outside the package.
- Duplicate scan 'path' is now relative to the output root and the
delete endpoint accepts relative paths.
- /logs/files 'path' and /logs/stats 'log_directory' use the public
form; unexpected errors answer with a generic message.
A gallery root could be set to '/' (or 'C:\') through POST
/prompt_manager/settings because the deny list only matched a few
system prefixes. The root was persisted to config.json and fed into the
image-serving containment check, which then allowed any file on disk to
be read through /prompt_manager/images/serve/.
- GalleryConfig.validate_gallery_root() accepts a directory only when its
realpath lies inside a ComfyUI directory (folder_paths output/input/
temp/user) or a directory listed in PROMPT_MANAGER_EXTRA_GALLERY_ROOTS;
filesystem roots, the home directory, files and missing paths are
rejected.
- save_settings returns 400 and persists nothing when any root fails.
- _get_all_output_dirs() filters configured roots through the validator
and never falls back to a rejected root.
- PROMPT_MANAGER_CONFIG_PATH relocates config.json; load/save default
to it.