@@ -74,9 +74,10 @@ class Script(scripts.Script):
|
||||
enabled = getattr(p, 'dynthres_enabled', enabled)
|
||||
if not enabled:
|
||||
return
|
||||
if p.sampler_name in ["DDIM", "PLMS"]:
|
||||
raise RuntimeError(f"Cannot use sampler {p.sampler_name} with Dynamic Thresholding")
|
||||
if p.sampler_name == 'UniPC' and p.enable_hr:
|
||||
orig_sampler_name = p.sampler_name
|
||||
if orig_sampler_name in ["DDIM", "PLMS"]:
|
||||
raise RuntimeError(f"Cannot use sampler {orig_sampler_name} with Dynamic Thresholding")
|
||||
if orig_sampler_name == 'UniPC' and p.enable_hr:
|
||||
raise RuntimeError(f"UniPC does not support Hires Fix. Auto WebUI silently swaps to DDIM for this, which DynThresh does not support. Please swap to a sampler capable of img2img processing for HR Fix to work.")
|
||||
mimic_scale = getattr(p, 'dynthres_mimic_scale', mimic_scale)
|
||||
threshold_percentile = getattr(p, 'dynthres_threshold_percentile', threshold_percentile)
|
||||
@@ -89,6 +90,7 @@ class Script(scripts.Script):
|
||||
p.extra_generation_params["Dynamic thresholding enabled"] = True
|
||||
p.extra_generation_params["Mimic scale"] = mimic_scale
|
||||
p.extra_generation_params["Threshold percentile"] = threshold_percentile
|
||||
p.extra_generation_params["Sampler"] = orig_sampler_name
|
||||
if mimic_mode != "Constant":
|
||||
p.extra_generation_params["Mimic mode"] = mimic_mode
|
||||
p.extra_generation_params["Mimic scale minimum"] = mimic_scale_min
|
||||
@@ -99,13 +101,13 @@ class Script(scripts.Script):
|
||||
p.extra_generation_params["Power scheduler value"] = power_val
|
||||
# Note: the ID number is to protect the edge case of multiple simultaneous runs with different settings
|
||||
Script.last_id += 1
|
||||
fixed_sampler_name = f"{p.sampler_name}_dynthres{Script.last_id}"
|
||||
fixed_sampler_name = f"{orig_sampler_name}_dynthres{Script.last_id}"
|
||||
# Percentage to portion
|
||||
threshold_percentile *= 0.01
|
||||
# Make a placeholder sampler
|
||||
sampler = sd_samplers.all_samplers_map[p.sampler_name]
|
||||
sampler = sd_samplers.all_samplers_map[orig_sampler_name]
|
||||
dtData = dynthres_core.DynThresh(mimic_scale, threshold_percentile, mimic_mode, mimic_scale_min, cfg_mode, cfg_scale_min, power_val, experiment_mode, p.steps)
|
||||
if p.sampler_name == "UniPC":
|
||||
if orig_sampler_name == "UniPC":
|
||||
def uniPCConstructor(model):
|
||||
return CustomVanillaSDSampler(dynthres_unipc.CustomUniPCSampler, model, dtData)
|
||||
newSampler = sd_samplers_common.SamplerData(fixed_sampler_name, uniPCConstructor, sampler.aliases, sampler.options)
|
||||
@@ -117,7 +119,7 @@ class Script(scripts.Script):
|
||||
return result
|
||||
newSampler = sd_samplers_common.SamplerData(fixed_sampler_name, newConstructor, sampler.aliases, sampler.options)
|
||||
# Apply for usage
|
||||
p.orig_sampler_name = p.sampler_name
|
||||
p.orig_sampler_name = orig_sampler_name
|
||||
p.sampler_name = fixed_sampler_name
|
||||
p.fixed_sampler_name = fixed_sampler_name
|
||||
sd_samplers.all_samplers_map[fixed_sampler_name] = newSampler
|
||||
|
||||
Reference in New Issue